Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
1.
Acta ortop. bras ; 31(2): e264848, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1439135

ABSTRACT

ABSTRACT Objective: To evaluate the citation of the ligament in the magnetic resonance imaging (MRI) reports and confirm its presence and injury in the images of exams performed in the acute phase retrospectively. Methods: In total, 103 patients who underwent anterior cruciate ligament (ACL) reconstruction in 2019 were included. The images were reanalyzed by two radiologists. Results: In the first analysis, only one report mentioned the anterolateral ligament (ALL) and its injury (0.97%). On reanalysis, ALL was visualized in almost all cases (95% and 97%). An injury was found in 53 (51.5%) cases by radiologist A and in 56 (54.4%) cases by radiologist B. The injury was diagnosed by both in 39 (37.9%) cases (p < 0.0001). Radiologists disagreed regarding the injury (Kappa = 0.411). Conclusion: The reports failed to describe the ligament and diagnose a significant number of injuries. The analysis of conventional resonance images still presents divergences in the diagnosis of ALL injury associated with the ACL among radiologists. Level of Evidence IV, Case Series.


RESUMO Objetivo: Avaliar, de forma retrospectiva, a citação do ligamento anterolateral (LAL) em laudos de ressonância magnética (RM) e confirmar sua presença e lesão nas imagens de exames feitos na fase aguda. Métodos: Foram incluídos 103 pacientes submetidos à reconstrução do ligamento cruzado anterior (LCA) em 2019, cujas imagens foram reanalisadas por dois radiologistas. Resultados: Em primeira análise, apenas um laudo citava o LAL e sua lesão (0,97%); enquanto na reanálise, o LAL foi visualizado em quase todos os casos (95% pelo radiologista A e 97% pelo radiologista B). Foi encontrada lesão em 53 (51,5%) casos pelo radiologista A e 56 (54,4%) pelo radiologista B. Lesão foi diagnosticada por ambos em 39 (37,9%) casos (p < 0,0001). Houve divergência entre os radiologistas com relação à lesão (KappaL = 0,411). Conclusão: Os laudos deixaram de descrever o ligamento e diagnosticar um número significativo de lesões. A análise das imagens convencionais de ressonância ainda gera divergências no diagnóstico da lesão do LAL associada ao LCA entre os radiologistas. Nível de Evidência IV, Série de Casos.

2.
Acta ortop. bras ; 31(spe2): e262186, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1439155

ABSTRACT

ABSTRACT Objective Compare the results of medial unicompartmental knee arthroplasty (UKA) using a mobile platform and total knee arthroplasty (TKA) in patients with isolated medial osteoarthritis. Methods Retrospectivecross-sectional study. Preoperative radiographs of 602 patientswho underwent knee arthroplastybetween February 2017 and February 2020 were evaluated. Isolated medial osteoarthritis was found in 125 patients. Of these, 57 underwent UKA and 68 TKA. With chart analysis and telephone interviews, we compared patients' clinical outcomes and degree of satisfaction. The statistical analysis used a confidence level of 5%. Results The group of UKA patients obtained 65.8% of favorable results against 79.1% of those undergoing TKA in the function questionnaire (p<0.0001). The complication rate was statistically similar between the groups(p>0.5). Most patients were satisfied or very satisfied in both groups (88.6% of UKA and 91.2% of TKA) (p>0.999). Conclusion Patients submitted to UKA or TKA have presented the same degree of satisfaction and rate of postoperative complications when comparing patients with isolated medial osteoarthritis. UKA patients had less favorable results onthe clinical functional questionnaire than patients undergoing total arthroplasty. Level Of Evidence III;Retrospective Study.


RESUMO Objetivo Comparar os resultados da artroplastia unicompartimental do joelho (UKA) medial com plataforma móvel e artroplastia total do joelho (TKA) em pacientes com osteoartrose medial isolada. Métodos Estudo transversal retrospectivo. Foram avaliadas radiografias pré-operatórias de 602 pacientes submetidos à artroplastia de joelho entre fevereiro de 2017 e fevereiro de 2020. A osteoartrose medial isolada foi encontrada em 125 pacientes, destes em 57 haviam sido submetidos a UKA e 68 TKA. Com análise de prontuários e entrevistas telefônicas comparamos os resultados clínicos e o grau de satisfação dos pacientes. A análise estatística utilizou nível de confiança de 5%. Resultados O grupo de pacientes com UKA obteve 65,8% de resultados favoráveis contra 79,1% daqueles submetidos à TKA no questionário de função (p<0,0001). A taxa de complicações foi estatisticamente semelhante entre os grupos (p>0,5). A maioria dos pacientes estava satisfeita ou muito satisfeita em ambos os grupos (88,6% de UKA e 91,2% de TKA) (p>0,999). Conclusão Pacientes submetidos a UKA ou TKA apresentaram o mesmo grau de satisfação e taxa de complicações pós-operatórias quando comparados pacientes com osteoartrite medial isolada. Os pacientes da UKA apresentaram resultados menos favoráveis ao questionário clínico funcional do que os pacientes submetidos à artroplastia total. Nível de Evidência III; Estudo Retrospectivo.

3.
Acta ortop. bras ; 30(3): e241172, 2022. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1374145

ABSTRACT

ABSTRACT Objective: To assess clinical results of patients who underwent medial patellofemoral ligament (MPFL) reconstruction after a minimum of two years of follow-up. Methods: Patients' medical records were assessed for residual instability, patient satisfaction, and post-operative functional outcomes. Results: Fifty-one patients were analyzed, out of which 56.87% were women. Patients' mean age was 30.8 years (16 to 57 years). The mean follow-up time was 68.7 months (37 to 120 months). Length between first dislocation and surgery was less than 1 year for 58.82% of patients, between 1 and 5 years for 37.25%, and over 5 years for 3.93%. Patients showed a high degree of satisfaction (96.08% would undergo surgery again), with recurrence rate of 11.76%. Twenty-two patients reported knee symptoms, including pain from movements (72.72%), weakness (18.18%), constant pain (13.63%), and crepitus (4.54%). Considering dissatisfied patients, patients with dislocation recurrence, and patients with symptoms, five cannot practice physical activity, out of which only three blame their knee. Conclusion: MPFL reconstruction showed a recurrence rate of 11.7%, with high patient satisfaction, good functional results, and high rate of return to sports, after a minimum of two years of follow-up. Level of Evidence IV, Case Series.


RESUMO Objetivo: Avaliar o resultado clínico de pacientes submetidos à reconstrução do ligamento patelofemoral medial (LPFM), acompanhados por mínimo de dois anos. Métodos: Avaliação de prontuários para informações sobre instabilidade residual, satisfação do paciente e resultado funcional pós-operatório. Resultados: Foram analisados 51 pacientes. 56,87% do sexo feminino e média etária 30,8 anos (16 a 57). Tempo médio de acompanhamento de 68,7 meses (37 a 120). Intervalo entre primeira luxação e cirurgia foi menos de 1 ano em 58,82%, entre 1 e 5 anos em 37,25% e mais de 5 anos para 3,93%. Os pacientes apresentaram alto grau de satisfação (96,08% fariam a cirurgia novamente), com 11,76% de recidiva. Houve persistência de sintomas em 22 pacientes, sendo dor ao movimento o principal (72,72%), seguido de fraqueza (18,18%), dor constante (13,63%) e crepitações (4,54%). Somando os pacientes insatisfeitos aos que tiveram recidiva da instabilidade e os sintomáticos, 5 não conseguem praticar atividade física, mas apenas 3 por causa do joelho. Conclusão: A reconstrução isolada do LPFM demonstrou índice de recidiva de 11,7%, com alto nível de satisfação dos pacientes, ótimos resultados funcionais e alta taxa de retorno ao esporte, em acompanhamento mínimo de 2 anos. Nível de Evidência IV, Série de Casos.

4.
Acta ortop. bras ; 30(1): e253870, 2022. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1355582

ABSTRACT

ABSTRACT Introduction To compare the functional results, satisfaction rates, and revisions of total knee arthroplasties performed by the same surgical team using either Brazilian or imported implants, with a minimum follow-up of 5 years after surgery. Materials and Methods A retrospective cohort study analyzing the medical records and interviews of patients who underwent total knee arthroplasty with Brazilian or imported implants with a minimum of 5 years after surgery. Results One hundred and fifty patients were evaluated (164 knees). In the functional questionnaire, 71% of patients had favorable answers in the group of patients who underwent surgery using the Brazilian prosthesis and 74.8% in the group with imported implants (p=0.634). There was no statistical difference in satisfaction between the groups, with 78.4% of patients satisfied or very satisfied in the Brazilian implant group and 90.7% in the imported implant group (p=0.053). Loosening of the implants was reported in 5.3% versus 4.7% (p>0.999). Conclusion The total knee arthroplasties performed by the same surgical team with a minimum follow-up period of 5 years showed similar levels of satisfaction, function, and complications with both the Brazilian and imported implants. Level of Evidence III, cohort study.


RESUMO Introdução Comparar resultados funcionais, índices de satisfação e revisões de artroplastias totais de joelho realizadas pela mesma equipe cirúrgica usando implantes brasileiros ou importados, com acompanhamento mínimo de cinco anos após a cirurgia. Material e Método Estudo de coorte retrospectivo com análise de prontuários e entrevistas de pacientes submetidos à artroplastia total do joelho com implantes brasileiros e importados com no mínimo cinco anos de pós-operatório. Resultados Foram avaliados 150 pacientes (164 joelhos). No questionário funcional, encontramos 71% dos pacientes com respostas favoráveis no grupo de pacientes submetidos à cirurgia com uso de próteses brasileiras e 74,8% no grupo com implantes importados (p = 0,634). Em relação à satisfação, não houve diferença estatística entre os grupos com 78,4% dos pacientes satisfeitos ou muito satisfeitos no grupo com implante brasileiro e 90,7% no grupo com implante importado (p = 0,053). A ocorrência de soltura dos implantes foi relatada em 5,3% versus 4,7% (p > 0,999). Conclusões As artroplastias totais de joelho realizadas pela mesma equipe cirúrgica com acompanhamento mínimo de cinco anos apresentaram níveis semelhantes de satisfação, função e complicações com os implantes brasileiros e importados. Nível de evidência III, estudo de coorte.

5.
Acta ortop. bras ; 29(6): 312-315, Nov.-Dec. 2021. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1349905

ABSTRACT

ABSTRACT Objective: To examine and compare the clinical efficacy of intraarticular epsilon aminocaproic acid (EACA) and tranexamic acid (TXA) in total knee arthroplasty (TKA). Methods: This study was a prospective, single-center, double-blinded randomized controlled trial, including sixty patients with osteoarthritis of the knee divided into two groups of 30 patients. In the TXA group, 1 g of TXA (0.05 g/ml) was applied intraarticularly, and in the EACA group, 4 g of EACA (0.2 g/ml) was applied intraarticularly. Serum hemoglobin (Hgb) and hematocrit (Htb) were measured during the preoperatively and 24 and 48 hours postoperatively. The range of motion and pain were evaluated by clinical examination. To evaluate knee function before and 2 months after surgery, the Western Ontario and McMaster Universities Index (WOMAC) questionnaire was used. Results: In total, 56 (93.3%) patients were evaluated up to the second postoperative month. No significant difference between the groups (p > 0.05) was found in the decrease in Hgb or Htb at 24 or 48 hours. Regarding assessment of the pain, WOMAC score and gain in knee flexion, no significant advantages up to 60 days after surgery (p > 0.05) were found. Conclusions: The decrease in Hgb and Htb during the first 48 hours postoperatively and the risk of transfusion were similar with the intraarticular use of 1 g of TXA and 4 g of EACA in TKA. The possible benefits regarding knee pain, gain in flexion and function were also similar for the two drugs. Level of Evidence II, Randomized, Double-Blinded, Single-Centre, Prospective Clinical Trial.


RESUMO Objetivo: Avaliar e comparar a eficácia clinica do uso intra-articular do ácido épsilon aminocaproico (AEAC) versus o ácido tranexâmico (ATX) na prótese total do joelho. Métodos: Estudo clínico prospectivo, centro-único, duplo-cego e randomizado. Sessenta pacientes com osteoartrose de joelho foram incluídos. Os participantes foram divididos em dois grupos de 30 pacientes. No grupo ATX, foi aplicado 1 g de ATX (0.05 g/ml) intra-articular e, no grupo AEAC, foram aplicados 4 g de AEAC (0.2 g/ml) intra-articular. Valores séricos da hemoglobina (Hb) e hemtatócrito (Ht) foram dosados no pré-operatório e com 24 e 48 horas após a cirurgia. A amplitude de movimento e a dor também foram avaliadas no exame clínico. O índice WOMAC foi utilizado para avaliar a função do joelho antes e após dois meses da cirurgia. Resultados: Foram avaliados 56 (93.3%) pacientes até o segundo mês pós-operatório. Depois da cirurgia, não houve diferenças entre os grupos (p > 0.05) na queda do valor de Hb e Ht com 24 ou 48 horas. Com relação à avaliação da dor, WOMAC e ganho de flexão do joelho, não houve vantagem significativa para nenhum dos grupos até os 60 dias depois da cirurgia(p > 0.05). Conclusão: A queda do valor da Hb e do Ht durante as primeiras 48 horas pós-operatórias e o risco de transfusão foram similares com o uso intra-articular de 1 g de ATX e 4 g de AEAC na artroplastia total do joelho. Os possíveis benefícios com relação ao controle da dor, ganho de flexão e função foram similares entre as duas drogas. Nível de Evidência II, Ensaio-Clínico Prospectivo, Randomizado, Duplo Cego, Centro-Único.

6.
Acta ortop. bras ; 27(5): 248-251, Sept.-Oct. 2019. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1038172

ABSTRACT

ABSTRACT Objective: To evaluate the efficacy of platelet-rich plasma (PRP) and tranexamic acid (TXA) applied in total knee arthroplasty. Methods: We selected and randomized 84 patients. TXA was applied in 23 patients, PRP in 20, and PRP in combination with TXA in 20. Hemoglobin was measured preoperatively and 24 and 48 hours postoperatively. The function questionnaire, pain scale and gain of knee flexion were monitored until the second postoperative year. Results: There was a difference (p <0.01) in the decrease in hemoglobin 48 hours after surgery between the TXA group and the control and PRP groups. In terms of pain, the TXA group at 24 and 48 hours after surgery and the PRP group at 48 hours after surgery showed advantages (p <0.01). Knee flexion gain in the first 24 hours postoperatively was better in the TXA group (p <0.05). Conclusion: TXA was effective in lowering the drop in hemoglobin level, reducing pain and improving movement gain 48 hours after the procedure. PRP was not effective in reducing bleeding or improving knee function after arthroplasty, but provided better control of postoperative pain. Level of Evidence I, Randomized, blinded, prospective clinical trial.


RESUMO Objetivo: Avaliar a eficácia do plasma rico em plaquetas (PRP) e do ácido tranexâmico (ATX) aplicados na artroplastia total do joelho. Métodos: Selecionamos e randomizamos 84 pacientes. ATX foi aplicado em 23 pacientes, PRP em 20, e PRP associado a ATX em 20. A hemoglobina foi medida no pré-operatório e nas 24 e 48 horas após a cirurgia. O questionário de função, a escala de dor e o ganho de flexão do joelho foram verificados até o segundo ano de pós-operatório. Resultados: Houve diferença(p < 0,01) na diminuição da hemoglobina 48 horas após a cirurgia entre o grupo ATX e os grupos controle e PRP. Na dor, o grupo ATX 24 e 48 horas após a cirurgia e o grupo PRP 48 horas após a cirurgia apresentaram vantagens (p < 0,01). O ganho de flexão do joelho nas primeiras 24 horas de pós-operatório foi melhor no grupo ATX (p < 0,05). Conclusão: O ATX foi eficaz na diminuição da queda da hemoglobina, reduzindo a dor e melhorando o ganho de movimento em 48 horas após o procedimento. O PRP não foi eficaz na redução do sangramento ou na melhora da função do joelho após a artroplastia, mas proporcionou melhor controle da dor pós-operatória. Nível de Evidência I, Randomizado, duplo cego, ensaio clínico prospectivo.

7.
Acta ortop. bras ; 26(2): 94-97, Mar.-Apr. 2018. tab, graf
Article in English | LILACS | ID: biblio-949733

ABSTRACT

ABSTRACT Purpose: To present a technical variation in tibial fixation of quadruple hamstring grafts during anatomic reconstruction of the anterior cruciate ligament (ACL). The secondary purpose was to decrease the costs associated with this procedure. Methods: Twenty patients who underwent ACL reconstruction were selected. A tibial tunnel was constructed using standard techniques, and a femoral tunnel was anatomically created using the outside-in technique. The hamstring autograft was passed (with its bend) into the tibial tunnel and affixed to the tibia using the suspensory technique and a simple staple. Femoral fixation was performed using a titanium interference screw. The patients underwent postoperative evaluations at 0, 3, 6 and 12 months using the subjective International Knee Documentation Committee (IKDC) form and Lysholm knee scores. Results: The IKDC and Lysholm score results improved over time (p<0.001) without major complications. The cost of the procedure could be reduced by using lower-cost hardware (staples). Conclusion: The proposed technique for anatomic ACL reconstruction using inverted hamstring grafts with their bend in the tibial tunnel, suspension-type fixation using a staple demonstrated good to excellent results after 1 year of follow up, with lower aggregate costs. Level of Evidence IV; Case series.


RESUMO Objetivo: Apresentar uma variação técnica na fixação do enxerto quádruplo de tendões flexores à tíbia na reconstrução anatômica do ligamento cruzado anterior (LCA). O objetivo secundário é diminuir o custo associado ao procedimento. Métodos: Foram selecionados 20 pacientes que seriam submetidos à reconstrução do LCA. O túnel tibial foi realizado usando técnica padrão, e o túnel femoral foi realizado pela técnica anatômica de fora para dentro. O enxerto (tendões flexores autólogos) foi passado com sua dobra dentro do túnel tibial e fixado com um agrafe simples pela técnica de suspensão. A fixação femoral foi realizada com parafuso de interferência de titânio. Os pacientes foram avaliados no pré-operatório e aos 3, 6 e 12 meses pós-operatórios usando o questionário International Knee Documentation Committee (IKDC) subjetivo e o questionário de Lysholm. Resultados: Os resultados dos escores dos questionários IKDC e Lysholm tiveram sempre melhora com o tempo (p < 0,001) sem maiores complicações. O custo total da cirurgia foi reduzido usando material de custo menor (agrafe). Conclusão: A técnica proposta para reconstrução anatômica do LCA com enxerto de tendões flexores invertido com sua dobra no túnel tibial, com fixação tipo suspensão com um agrafe, mostrou bons a excelentes resultados após 1 ano de acompanhamento, com menor custo agregado. Nível de Evidência IV; Série de casos.

8.
Rev. bras. ortop ; 50(2): 186-194, Mar-Apr/2015. tab, graf
Article in English | LILACS | ID: lil-748353

ABSTRACT

OBJECTIVE: To evaluate the efficacy of platelet-rich plasma regarding healing, pain and hemostasis after total knee arthroplasty, by means of a blinded randomized controlled and blinded clinical study. METHODS: Forty patients who were going to undergo implantation of a total knee prosthesis were selected and randomized. In 20 of these patients, platelet-rich plasma was applied before the joint capsule was closed. The hemoglobin (mg/dL) and hematocrit (%) levels were assayed before the operation and 24 and 48 h afterwards. The Womac questionnaire and a verbal pain scale were applied and knee range of motion measurements were made up to the second postoperative month. The statistical analysis compared the results with the aim of determining whether there were any differences between the groups at each of the evaluation times. RESULTS: The hemoglobin (mg/dL) and hematocrit (%) measurements made before the operation and 24 and 48 h afterwards did not show any significant differences between the groups (p > 0.05). The Womac questionnaire and the range of motion measured before the operation and up to the first two months also did not show any statistical differences between the groups (p > 0.05). The pain evaluation using the verbal scale showed that there was an advantage for the group that received platelet-rich plasma, 24 h, 48 h, one week, three weeks and two months after the operation (p < 0.05). CONCLUSIONS: In the manner in which the platelet-rich plasma was used, it was not shown to be effective for reducing bleeding or improving knee function after arthroplasty, in comparison with the controls. There was an advantage on the postoperative verbal pain scale. .


OBJETIVOS: Avaliar, por meio de um estudo clínico, randomizado, controlado e cego, a eficácia do plasma rico em plaquetas na cicatrização, dor e hemostasia após artroplastia total do joelho. MÉTODOS: Foram selecionados 40 pacientes que seriam submetidos a prótese total do joelho e randomizados. Em 20 desses pacientes foi aplicado o plasma rico em plaquetas antes do fechamento da cápsula articular. Foram feitas dosagens de hemoglobina (mg/dL) e hematócrito (%) no pré-operatório, após 24 e 48 horas da cirurgia. Foram aplicados o questionário Womac e a escala verbal da dor e medidas as amplitudes de movimento do joelho até o segundo mês pós-operatório. A análise estatística comparou os resultados a fim de comprovar haver diferença entre os grupos em cada um dos momentos da avaliação. RESULTADOS: Medidas do valor da hemoglobina (mg/dL) e hematócrito (%) feitas no pré-operatório, após 24 e 48 horas da cirurgia, não mostraram diferenças significativas entre os grupos (p > 0,05). O questionário Womac e a amplitude de movimento medida no pré-operatório e até os dois primeiros meses também não mostraram diferenças estatísticas entre os grupos (p > 0,05). A avaliação da dor por meio da escala verbal mostrou vantagem no grupo que usou o plasma rico em plaquetas após 24 e 48 horas, uma e três semanas e dois meses de pós-operatório (p < 0,05). CONCLUSÕES: Da maneira com que foi usado, o plasma rico em plaquetas não se mostrou efetivo para reduzir sangramento ou melhorar a função do joelho após a artroplastia em comparação com os controles. Houve vantagem na escala verbal de dor pós-operatória. .


Subject(s)
Humans , Male , Female , Middle Aged , Aged, 80 and over , Arthroplasty, Replacement, Knee , Blood Platelets , Blood Transfusion , Hemorrhage , Plasma
9.
Clinics ; 69(10): 694-698, 10/2014. tab, graf
Article in English | LILACS | ID: lil-730462

ABSTRACT

OBJECTIVES: Treatments for injured articular cartilage have not advanced to the point that efficient regeneration is possible. However, there has been an increase in the use of platelet-rich plasma for the treatment of several orthopedic disorders, including chondral injuries. Our hypothesis is that the treatment of chondral injuries with platelet gel results in higher-quality repair tissue after 180 days compared with chondral injuries not treated with gel. METHODS: A controlled experimental laboratory study was performed on 30 male rabbits to evaluate osteochondral injury repair after treatment with or without platelet gel. Osteochondral injuries were surgically induced in both knees of each rabbit at the medial femoral condyle. The left knee injury was filled with the platelet gel, and the right knee was not treated. Microscopic analysis of both knee samples was performed after 180 days using a histological grading scale. RESULTS: The only histological evaluation criterion that was not significantly different between treatments was metachromasia. The group that was treated with platelet gel exhibited superior results in all other criteria (cell morphology, surface regularity, chondral thickness and repair tissue integration) and in the total score. CONCLUSION: The repair tissue was histologically superior after 180 days in the study group treated with platelet gel compared with the group of untreated injuries. .


Subject(s)
Animals , Male , Rabbits , Cartilage, Articular/injuries , Knee Injuries/therapy , Platelet-Rich Plasma , Cartilage, Articular/pathology , Disease Models, Animal , Gels/therapeutic use , Knee Injuries/pathology , Reproducibility of Results , Time Factors , Treatment Outcome , Wound Healing
10.
Acta ortop. bras ; 20(5): 258-261, 2012. graf, tab
Article in Portuguese | LILACS | ID: lil-658908

ABSTRACT

OBJETIVO: A cirurgia de reconstrução do LCA é hoje uma das mais realizadas e o controle da dor pós-operatória faz parte das prioridades do cirurgião. Dentro do arsenal de analgesia temos a aplicação intra-articular de drogas, sendo a mais estudada a bupivacaina associada ou não a morfina. Neste estudo comparamos a aplicação de bupivacaina associada ou não a morfina com grupo controle, após reconstrução do LCA com enxerto de tendões flexores. MÉTODOS: Quarenta e cinco pacientes foram randomizados em três grupos, sendo que no grupo I foi aplicado ao fim da cirurgia 20ml de soro fisiológico intra-articular, no grupo II 20ml de bupivacaina 0,25% e no grupo III bupivacaina 0,25% associado a 1mg de morfina. Os grupos foram avaliados quanto ao grau de dor pela escala analógica visual com 6, 24 e 48 horas de pós-operatório. RESULTADOS: O grupo III teve menos dor em todos os momentos, porém a dor não foi tão intensa em todos os grupos a ponto de necessitar medicações extras além do protocolo estabelecido. CONCLUSÃO: A aplicação intra-articular destas medicações pós-reconstrução do LCA com enxerto dos tendões flexores quando realizada sob anestesia raquideana não traz vantagens suficientes para fazer seu uso regularmente. Nível de Evidência II, Ensaio Clínico Randomizado de Menor Qualidade.


OBJECTIVE: Reconstructive surgery of the ACL is one of the most commonly performed surgeries today and the control of postoperative pain is part of the priorities of the surgeon. Within the arsenal of analgesia we have the intra-articular application of drugs, and the most studied one is bupivacaine with or without morphine. This study compared the application of bupivacaine with or without morphine with a control group after ACL reconstruction with flexor tendon graft. METHODS: Forty-five patients were randomized into three groups: in group I, 20 ml of saline were applied intra-articularly at the end of the surgery; in group II, 20 ml of bupivacaine 0.25%; and in group III, bupivacaine 0.25% associated with 1 mg of morphine. The groups were assessed for degree of pain by the Visual Analog Scale at 6, 24 and 48 hours postoperatively. RESULTS: Group III had less pain at all times, but the pain was not as intense in all groups to the point of needing extra medications beyond the established protocol. CONCLUSION: The intra-articular application of these medications after ACL reconstruction with flexor tendon graft when performed under spinal anesthesia is not useful enough to use regularly. Level of Evidence II, Lesser quality RCT.


Subject(s)
Humans , Male , Female , Adolescent , Young Adult , Middle Aged , Anesthesia , Bupivacaine , Anterior Cruciate Ligament/surgery , Morphine , Pain Measurement , Tendons , Postoperative Care
11.
Acta ortop. bras ; 19(6): 338-341, 2011. tab
Article in Portuguese | LILACS | ID: lil-610488

ABSTRACT

OBJETIVO: A fixação femoral na reconstrução do Ligamento Cruzado Anterior (LCA) com enxerto de tendões flexores pode variar muito de acordo com a disposição dos materiais e a experiência do cirurgião. Porém os trabalhos que comparam os sistemas de fixação são efetuados na maioria das vezes em cadáveres ou em animais, sem avaliar os resultados clínicos, prejudicando sua comparação com pacientes humanos vivos. Neste artigo avaliamos o resultado clínico de dois métodos de fixação do enxerto ao fêmur (parafuso de interferência de titânio e parafuso transcondilar de titânio) para saber se, do ponto de vista clinico e subjetivo, há diferença entre estes métodos. MÉTODOS: Foram selecionados 40 pacientes com lesão do LCA sendo que 20 pacientes tiveram seu enxerto fixado ao fêmur com parafuso de interferência e 20 com parafuso transcondilar. Todos foram reavaliados com no mínimo dois anos de pós operatório para medição da gaveta anterior, Pivot Shift e teste de Lachman, além da obtenção dos questionário de Lysholm e IKDC (International Knee Documentation Committee). RESULTADOS: Os resultados não foram estatisticamente diferentes para os critérios avaliados. CONCLUSÃO: As duas formas de fixação são eficientes para esta técnica dentro dos parâmetros estabelecidos. Nível de Evidência II, Estudo Prospectivo Comparativo.


OBJECTIVE: Femoral fixation in ACL reconstruction with flexor tendon grafts can vary greatly according to the provision of materials and the surgeon's experience. But studies comparing fixation systems are most often performed on cadavers or animals, without evaluating the clinical results, which affects their comparison with live human patients. This article evaluates the clinical and subjective outcomes of two methods of graft fixation to the femur (Titanium interference screw and titanium transcondilar device) to determine whether there is any difference between these methods. METHODS: Forty patients with ACL injury were selected. Of these, 20 had their graft fixed to the femur with interference screw and 20 with the transcondylar device. All the patients were reevaluated at least two years postoperatively by the anterior drawer test, pivot shift test and Lachman test, as well as obtaining the Lysholm and IKDC (International Knee Documentation Committee) scores. Results: The results were not statistically different for the criteria evaluated, which leads to the conclusion that. CONCLUSION: Both forms of fixation are effective for this technique, within the parameters established. Level of Evidence II, Prospective Comparative study.


Subject(s)
Humans , Male , Female , Adolescent , Young Adult , Anterior Cruciate Ligament , Bone Screws , Fracture Fixation , Fracture Fixation/methods , Anterior Cruciate Ligament/surgery , Anterior Cruciate Ligament/injuries
12.
Rev. bras. ortop ; 38(3): 117-126, mar. 2003. ilus, tab, graf
Article in Portuguese | LILACS | ID: lil-360779

ABSTRACT

O objetivo desta investigação experimental foi avaliar o perfil mecânico de uma técnica de sutura tendínea realizada com três tipos diferentes de fios cirúrgicos utilizando tendões de cães, para avaliação do desempenho de cada um dos três fios quando submetidos às mesmas solicitações. Foram utilizados 18 cães (13 machos e cinco fêmeas), dos quais foram obtidos o tendão flexor profundo do terceiro dedo de ambos os membros anteriores. A sutura foi realizada nos tendões do lado direito com três diferentes fios por sorteio (seis animais por grupo: grupo I com Mononylon, grupo II com Prolene e grupo III com Ethibond). Os corpos de prova de ambos os lados (direito: suturado, esquerdo: controle) foram fixados em garras especialmente desenvolvidas e submetidos a ensaio de tração axial à velocidade de 40mm/min, com célula de carga de 5.000N. A ruptura dos tendões suturados ocorreu sempre no nó e, nos controles, na porção média do corpo de prova. Após o ensaio, o programa da máquina forneceu os valores da carga máxima (N), alongamento relativo na carga máxima (por cento) e módulo de elasticidade (MPa). Os resultados foram avaliados pela técnica de análise de variância dos pontos médios complementado com a construção dos intervalos de confiança simultâneos no nível de 5 por cento de significância. Não foi constatada diferença estatisticamente significativa nos parâmetros carga máxima e módulo de elasticidade entre os tendões tratados, independentemente do tipo de fio, sendo todos inferiores ao respectivo controle. No parâmetro alongamento relativo na carga máxima o fio de náilon teve resultado superior ao dos outros fios (que tiveram resultado semelhante ao controle), sugerindo formação de gap antes da ruptura.


Subject(s)
Animals , Dogs , Sutures , Tendons , Biomechanical Phenomena
SELECTION OF CITATIONS
SEARCH DETAIL